GA/T 1368-2017: Police digital trunking communication system -- Technical specifications for engineering
GA/T 1368-2017
GA
PUBLIC SECURITY INDUSTRY STANDARD
OF THE PEOPLE?€?S REPUBLIC OF CHINA
ICS 33.060.01
A 90
Police Digital Trunking Communication System - Technical
Specifications for Engineering
ISSUED ON: FEBRUARY 8, 2017
IMPLEMENTED ON: FEBRUARY 8, 2017
Issued by: Ministry of Public Security of the People?€?s Republic of China
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative References ... 5
3 Terms, Definitions and Abbreviations ... 6
4 General ... 7
5 PDT Communication System Design ... 7
6 Construction Requirements ... 15
7 Project Acceptance... 21
Appendix A (Informative) Equipment Reference Indicators for Antenna System ... 30
Police Digital Trunking Communication
System - Technical Specifications for Engineering
1 Scope
This Standard specifies the requirements for the design, construction, and engineering
acceptance of the Police Digital Trunking (PDT) communication system.
This Standard applies to the construction, reconstruction, and expansion of the Police Digital
Trunking (PDT) communication system.
2 Normative References
The following documents are essential to the application of this Document. For the dated
documents, only the versions with the dates indicated are applicable to this Document; for the
undated documents, only the latest version (including all the amendments) is applicable to this
Document.
GB 50174-2008 Code for Design of Electronic Information System Room
GB 50201-2014 Standard for flood control
GB 50348-2004 Technical code for engineering of security and protection system
GB 50689-2011 Code for design of lightning protection and earthing engineering for
telecommunication bureaus (Stations)
GA/T 1056-2013 Police digital trunking communication system?€?General technical
specifications
GA/T 1059-2013 Police digital trunking communication system?€?Security technical
specifications
GA/T 1255-2016 Police digital trunking communication system Technical requirements
and measurement methods for radio frequency equipment
GA/T 1367-2017 Police digital trunking communication system-measurement methods for
function
GF 005-1994 Technical specification for interface for special mobile communication
--- Security docking platform completes the secure docking of the PDT system and the
public security information network, including front-end servers, network gates, back-
end servers, firewalls and other equipment to ensure the security of the public security
information network and the PDT private network; and ensure to realize real-time
interaction, complete functions and no missing of the security of the voice and data
services of PDT private network and the public security information network;
--- Other supporting equipment such as database servers, network management servers, etc.
provide necessary support for the operation of the soft switch system;
--- The mobile switch office should consider hot backup for disaster recovery in different
locations.
5.4 Transmission link design
5.4.1 Overview
The transmission link mainly includes the following links: links between base stations and
switching centers, links between switching centers, links between switching centers and
management clients, scheduling clients, and monitoring clients.
When using the computer room provided by social resources and the link rented from the public
network telecommunications operator, it shall not be directly connected to the public security
information network.
5.4.2 Link form
The link shall use an IP dedicated link.
5.4.3 Link bandwidth requirements
IP links are used to connect switching centers.
The link bandwidth requirements between switching centers are 5Mbps~10Mbps.
The link bandwidth between base stations and switches is required to be no less than 64kbps
per carrier.
5.4.4 Transmission links between dispatch desks and management terminals
The remote network management/dispatching terminal is connected to the main switching
center using a link with a bandwidth of no less than 2Mbps.
5.4.5 Transmission links for monitoring terminals
On the basis of meeting the bandwidth of cluster services, the network bandwidth that supports
monitoring video transmission shall be selected to avoid affecting cluster services.
5.4.6 Reliability requirements
Key transmission links should adopt a dual backup design.
Link requirements between base stations and switching centers: network delay is no more than
50 ms, network jitter is no more than 20 ms, and packet loss rate is no more than 1??10-3.
Link requirements between switching centers: network delay is no more than 100ms, network
jitter is no more than 50ms, and packet loss rate is no more than 1??10-3.
5.5 Wireless network design
5.5.1 Overview
Wireless network design shall include site coverage planning, capacity design and frequency
configuration.
5.5.2 Wireless network coverage design
5.5.2.1 Principles of wireless network coverage design
In wireless network coverage design, the hanging height of antenna, antenna type, antenna
azimuth and down-tilt angle of the base station shall be determined based on the principle of
meeting the coverage range and reducing frequency interference.
5.5.2.2 Contents of wireless network coverage design
Wireless network coverage design shall include the following contents:
--- Site location;
--- Number of sites;
--- Site type;
--- Hanging height of antenna;
--- Wireless parameters (including transmission power, antenna gain, tilt angle, directional
pattern, antenna feed system loss, etc.);
--- Coverage prediction.
In order to solve the problem of mismatch in uplink and downlink communication distance
between the handset station and the base station, the following measures can be adopted:
--- Base station adopts diversity reception;
--- Base station receiving antenna uses high-gain directional antenna.
g) Determine the specific site location through on-site survey;
h) Adjust the initial site setting plan according to the actual site.
5.5.3 Wireless network capacity design
5.5.3.1 Contents of wireless network capacity design
The wireless network capacity design shall include the following:
--- Calculate the number of voice channels based on the volume of single call and group call
traffic;
--- Calculate the number of data channels based on the amount of satellite positioning data;
--- Consider 20%~30% redundancy.
5.5.3.2 Basic steps for wireless network capacity design
The design of digital trunking wireless capacity should follow the following basic steps:
a) Clarify the user capacity demand target;
b) Predict the traffic and data flow in the coverage area based on the traffic model;
c) Predict the traffic and data flow absorbed by each base station;
d) Determine the number of carriers configured for the base station based on the Irish
formula.
5.5.4 Wireless network frequency configuration
The frequency configuration shall comply with the following basic principles:
--- Use a frequency reuse method of no less than 12 groups;
--- No third-order intermodulation and no adjacent channel interference within the station;
--- The minimum channel frequency interval of the same combiner is no less than 250kHz;
--- No adjacent channel interference between adjacent stations, and no co-channel
interference between multiplexing stations;
--- When frequency reuse is used, the co-channel suppression, adjacent channel selectivity
and intermodulation response suppression indicators shall meet the requirements of
GA/T 1056-2013.
5.6 Service platform design
The service platform of the switching control center completes the service generation and
provision functions; mainly including service control points and application servers, such as
dispatch servers, recording servers, GIS servers, etc.
5.7 Equipment selection
The digital trunking communication system equipment shall meet the relevant requirements of
the PDT series standards and pass the inspection of the inspection department. The performance
indicators of supporting equipment such as antennas, feeders, combiners, splitters, duplexers,
etc. are shown in Appendix A.
5.8 Bureau (station) selection and requirements
5.8.1 Mobile switch office
The selection of the mobile switch office site shall be carried out in accordance with the relevant
provisions of GB 50174-2008.
The site of the mobile switch office should take into account factors such as convenient link
connection and convenient docking with other application systems; and select a machine room
with complete infrastructure and convenient operation and maintenance.
5.8.2 Base station
The base station shall be located near the planned and designed location; and the location
deviation shall be based on the principle of not causing frequency interference.
The base station site should be selected in a relatively high terrain, with buildings of appropriate
height or where there is a communication tower available. However, it should not blindly pursue
the height, which will cause the problem of insufficient effective coverage despite a large
coverage area.
The base station shall have a wide field of vision around it, and try to avoid tall obstacles higher
than the antenna height within 200m in the direction of the main lobe of the base station antenna.
When the base station site is selected in a civil building, the floor load shall be calculated
according to the weight, size and arrangement of all equipment in the station to determine
whether necessary reinforcement measures should be taken.
The site should be selected in a place with less man-made noise and other radio interference
environments, and should not be set up near high-power radio transmitters, high-power
television transmitters, high-power radar stations, etc.
The site shall be selected in a safe environment, and shall not be selected in buildings where
flammable and explosive materials are stacked, or near industrial enterprises that are prone to
fire and explosion hazards.
5.8.6 Lightning protection
The lightning protection and grounding design of the cluster mobile switch office and base
station shall be implemented in accordance with the relevant provisions of GB 50689-2011.
5.8.7 Environmental protection
The various impacts of cluster communication project construction on the surrounding
environment shall meet the relevant requirements of YD 5039-2009. The environmental
requirements inside the communication bureau (station) shall meet the relevant requirements
of YD/T 1821-2008 and YD/T 1712-2007.
6 Construction Requirements
6.1 Computer room and environmental safety
The construction and decoration of the computer room shall be constructed according to the
design requirements. The roof shall not leak; the room shall not seep; and the walls and floors
shall be flat and dense.
The location and specifications of the trough, reserved holes, embedded steel pipes, bolts, etc.
shall comply with the engineering design and installation requirements. The trough cover shall
be tight and solid, and there shall be no water seepage in the trough.
The computer room generally adopts upper wiring, and the ceiling shall not be installed. The
air inlet shall not be blocked when laying cables.
The interior decoration materials of the computer room shall be flame-retardant materials, the
reserved holes shall be equipped with flame-retardant safety covers; and the used wiring holes
shall be sealed with fire-proof mud.
The number, location and capacity of the lighting and sockets in the computer room meet the
configuration requirements; the installation process is good; and meet the use requirements.
It is strictly forbidden to store flammable and explosive dangerous goods in the computer room.
Anti-seismic measures shall comply with YD 5059-2005 and engineering design requirements.
Fire prevention measures shall comply with the relevant provisions of GB 50174-2008.
Flood control shall comply with the provisions on communication facilities in GB 50201-2014.
6.2 Cable runways and troughs
The installation of cable runways and troughs shall meet the following requirements:
--- The cable runway is straight, without obvious ups and downs, twists and skews;
--- The cable runway is parallel to the wall or cabinet arrangement;
--- The hanging installation meets the requirements of the engineering design, and is vertical,
neat and firm;
--- The ground pillars are installed vertically and firmly, and the columns in the same
direction are on the same straight line. When the columns hinder the installation of
equipment, they are moved appropriately;
--- The side supports and terminal reinforcement angle steels of the cable runway are
installed firmly, straight and flat;
--- The horizontal cable runway along the wall is parallel to the ground, and the vertical
cable runway along the wall is perpendicular to the ground;
--- All cable runways are reliably grounded;
--- The troughs are installed flat, straight and firm, and the troughs are arranged in a straight
line;
--- The expansion bolts used for all support reinforcements have the same length.
6.3 Equipment Installation
Equipment installation shall meet the following requirements:
--- Equipment installation position shall meet the requirements of engineering design plan;
--- Equipment racks shall be installed vertically;
--- Equipment panels of racks in the same row shall be on the same plane;
--- Rack anti-vibration reinforcement shall meet the requirements of YD 5059-2005 and
engineering design;
--- Anti-static measures for switching subsystem equipment shall meet the requirements of
equipment and engineering design.
6.4 Cable Laying
6.4.1 General requirements
When laying cables on the cable runway, they shall be tied together. The tied cables shall be
close to each other, straight and neat in appearance, with uniform spacing between wire buckles,
The wire buckles shall be moderately tight, and shall be tied and fixed on the first horizontal
iron.
--- A combined groundin...