1
/
z
12
PayPal, credit cards. Download editable-PDF and invoice in 1 second!
YY/T 1512-2017 English PDF (YYT1512-2017)
YY/T 1512-2017 English PDF (YYT1512-2017)
Běžná cena
$145.00 USD
Běžná cena
Výprodejová cena
$145.00 USD
Jednotková cena
/
za
Dostupnost vyzvednutí nebylo možné načíst
Delivery: 2 working-hours manually (Sales@ChineseStandard.net)
Need delivered in 3-second? USA-Site: YY/T 1512-2017
Get Quotation: Click YY/T 1512-2017 (Self-service in 1-minute)
Historical versions (Master-website): YY/T 1512-2017
Preview True-PDF (Reload/Scroll-down if blank)
YY/T 1512-2017: Biological evaluation of medical devices—Guidance on the conduct of biological evaluation within a risk management process
YY/T 1512-2017
YY
PHARMACEUTICAL INDUSTRY STANDARD
OF THE PEOPLE’S REPUBLIC OF CHINA
ICS 11.040.01
C 30
Biological Evaluation of Medical Devices -
Guidance on the Conduct of Biological
Evaluation within a Risk Management Process
(ISO/TR 15499.2016, MOD)
ISSUED ON. JULY 17, 2017
IMPLEMENTED ON. JULY 1, 2018
Issued by. China Food and Drug Administration
Table of Contents
Foreword ... 3
Introduction ... 5
1 Scope ... 7
2 Normative References ... 7
3 Terms and Definitions ... 8
4 Biological Evaluation is a Risk Management Activity ... 9
5 Risk Management Guidance ... 13
6 Guidance of Biological Evaluation in Specific Aspects ... 17
References ... 25
Foreword
This Standard is drafted in accordance with stipulations in GB/T 1.1-2009.
This Standard is modified in accordance with the Law of Redrafting on the basis of
ISO/TR 15499.2016 Biological Evaluation of Medical Devices - Guidance on the
Conduct of Biological Evaluation within a Risk Management Process.
In comparison with ISO/TR 15499.2016, there are several technical differences and
causes for these differences as follows.
-- In terms of normative references, there is an adjustment of technical differences
in this Standard to comply with national-level technical conditions. The condition
of such adjustment is intensively reflected in Chapter 2 “Normative References”.
Please see the specific adjustment below.
GB/T 16886.1-2011, which adopts equivalent international standards, is
adopted to replace ISO 10993-1.2009;
GB/T 16886.7, which adopts equivalent international standards, is adopted to
replace ISO 10993-7;
GB/T 16886.9, which adopts equivalent international standards, is adopted to
replace ISO 10993-9;
GB/T 16886.12, which adopts equivalent international standards, is adopted to
replace ISO 10993-12;
GB/T 16886.13, which adopts equivalent international standards, is adopted to
replace ISO 10993-13;
GB/T 16886.14, which adopts equivalent international standards, is adopted to
replace ISO 10993-14;
GB/T 16886.15, which adopts equivalent international standards, is adopted to
replace ISO 10993-15;
GB/T 16886.16, which adopts equivalent international standards, is adopted to
replace ISO 10993-16;
GB/T 16886.17, which adopts equivalent international standards, is adopted to
replace ISO 10993-17;
GB/T 16886.18, which adopts equivalent international standards, is adopted to
replace ISO 10993-18;
GB/T 16886.19, which adopts equivalent international standards, is adopted to
replace ISO 10993-19;
YY/T 0287-2017, which adopts equivalent international standards, is adopted
to replace ISO 13485.2016;
YY/T 0316-2016, which adopts equivalent international standards, is adopted
to replace ISO 14971.2007;
CNAS-CL01, which adopts equivalent international standards, is adopted to
replace ISO/IEC 17025.
Please be noted that certain content in this Standard might involve patents. The
institution that issues this Standard shall not undertake any responsibility of identifying
these patents.
This Standard is proposed by State Food and Drug Administration of the People’s
Republic of China.
This Standard is summarized by National Technical Committee 248 on Medical Device
Biological Evaluation Standardization (SAC/TC 248).
This Standard is drafted by. Shandong Quality Inspection Center for Medical Devices.
The main drafters of this Standard include. Liu Chenghu, Houli, Wuping.
Introduction
0.1 General Principles
This Standard provides guidance on the conduct of biological evaluation of medical
devices in accordance with the requirements in GB/T 16886.1-2011. Although GB/T
16886.1-2011 provides a general framework to the biological evaluation of medical
devices, more specific guidance is necessary during the practical application of this
Standard. Therefore, this Standard is formulated to provide guidance to users of GB/T
16886.1-2011. This Standard facilitates better understanding of the requirements in
GB/T 16886.1-2011 and elaborates various modes and methods that comply with the
requirements in GB/T 16886.1-2011.
Biological evaluation is a group of relatively broad design and verification activities
within the category of risk management process. Therefore, this Standard includes the
guidance of applying GB/T 16886.1-2011 during the risk management process in
accordance with the requirements in YY/T 0316-2016. As a part of the general
evaluation and development of medical devices, concepts and methods described in
this Standard can be taken into consideration during the establishment and
maintenance of a risk management process of biological evaluation.
With the scientific development, we have continuously intensified our grasp of the
fundamental mechanism of tissue reaction. Biological evaluation can be established
on the basis of the review of relevant scientific data, chemical analysis and necessary
in-vivo and in-vitro test. GB/T 16886.1-2011 stipulates a framework of planning
biological evaluation. Through the preferred adoption of chemical components, and in-
vitro models that can obtain equivalent relevant information with in-vivo models, the
quantity of experimental animals and the degree of exposure are controlled to the
minimum. The selection of an appropriate method for a specific medical device will
depend on the characteristics of the device, the availability of of relevant scientific data
and risk assessment.
During the assessment of the availability of the guidance in this Standard, the
requirements and guidance of applicable laws and regulations shall be taken into
consideration.
Organization groups can voluntarily include the whole or any part of the guidance in
this Standard in their risk management process.
The guidance included in this Standard can be assessed as background information
by assessors in the risk management process in institutions and regulatory authorities.
0.2 The Relations Among other Standards, Guidance Standards and
Regulatory Requirements
The relations among GB/T 16886.1-2011, this Standard, and medical device biological
Biological Evaluation of Medical Devices -
Guidance on the Conduct of Biological
Evaluation within a Risk Management Process
1 Scope
This Standard is applicable to the biological evaluation of medical devices in
accordance with the requirements in GB/T 16886.1-2011. This Standard does not add
or modify the requirements in GB/T 16886.1-2011. This Standard does not include
requirements of regulatory inspection or certification and assessment activities.
This Standard is applicable to all the biological evaluation of various types of medical
devices, including active, passive, implantable and non-implantable medical devices.
2 Normative References
The following documents are indispensable to the application of this Standard. In terms
of references with a specified date, only versions with a specified date are applicable
to this Standard. The latest version (including all the modifications) of references
without a specified date is also applicable to this Standard.
GB/T 16886.1-2011 Biological Evaluation of Medical Devices - Part 1. Evaluation
and Testing within a Risk Management Process (ISO 10993-1.2009, IDT)
GB/T 16886.7 Biological Evaluation of Medical Devices - Part 7. Ethylene Oxide
Sterilization Residuals (GB/T 16886.7-2015, ISO 10993-7.2008, IDT)
GB/T 16886.9 Biological Evaluation of Medical Devices - Part 9. Framework for
Identification and Quantification of Potential Degradation Products (GB/T 16886.9-
2001, ISO 10993-9.1999, IDT)
GB/T 16886.12 Biological Evaluation of Medical Devices - Part 12. Sample
Preparation and Reference Materials (GB/T 16886.12-2005, ISO 10993-12.2002,
IDT)
GB/T 16886.13 Biological Evaluation of Medical Devices - Part 13. Identification
and Quantification of Degradation Products from Polymeric Medical Devices
(GB/T 16886.13-2001, ISO 10993-13.1998, IDT)
GB/T 16886.14 Biological Evaluation of Medical Devices - Part 14. Identification
is a fundamental element of this biological evaluation plan. Patients obtain benefits
from the application of medical devices, and meanwhile, they also undertake potential
risks. These risks might differ in accordance with the characteristics and expected
purposes of specific medical devices. The acceptable level of risks of a specific
medical device is determined by the expected earnings of the medical device.
The consideration of biological (toxicological) risks of medical devices is merely an
aspect of various aspects that need to be taken into consideration during risk
assessment. Under some circumstances, the earnings of other characteristics, other
than the biological safety of materials, deserve special attention. For instance, the
optimal biologically safe material that can be obtained might not manifest acceptable
mechanical strength. Under this circumstance, it is necessary to consider materials
with a higher strength and acceptable biological safety. The premise of conducting
biological evaluation is to recognize that this is merely a part of the whole risk
management process that is needed for the design and development of medical
devices.
Material selection and risk analysis are organic constituent parts of medical device
design. The selection of materials plays a decisive role in biological safety evaluation.
Furthermore, relevant data can be collected by starting with a systematic mode. In
accordance with YY/T 0287-2017 and Y/T 0316-2016, criteria of acceptable biological
(toxicological) risks shall be determined at the beginning of design. Since the variation
of primitive materials, ingredients and process might influence the biocompatibility of
products, these considerations shall be included in risk assessment. Biological safety
evaluation shall be designed and conducted to verify the compliance with specific
safety criteria. As a constituent part of risk management plan, this evaluation is
centralized in the identification of hazards and the estimation of relevant risks. In
thorough risk assessment, toxicological hazards and the degree of exposure shall be
characterized.
A main content of hazard identification is material characterization, including.
-- Definition and characterization of each variety of material (including appropriate
alternative material);
-- Identification of hazards, additives and processing aids in materials;
-- Identification of the potential influence of downstream processing process (for
example, chemical reaction in material composition or sterilization of ultimate
products) on chemicals in the ultimate products;
-- Identification of chemicals that might be released during the usage of products
(for example, the intermediate or ultimate degradation product of a certain
degradable implant);
-- Estimation of intake (total intake or clinical intake);
of exposure of material composition. In risk analysis, each route of exposure and toxic
effect of risk of each variety of material/material composition shall be estimated in a
well-organized order.
Therefore, materials and material compositions on medical devices that are directly
and indirectly exposed to patients shall be identified and characterized first in risk
analysis. In consideration of the existence of any production additives, processing aids
or other potential pollutants, for example, disinfectant, risk analysis shall be conducted
on the ultimate product under the state of manufacture. Furthermore, the influence of
the processing process on material compositions and chemicals shall also be taken
into consideration (including the influence on the basal body and the surface). The
possibility of generating toxic residues in continuous application of medical devices, or
in the production, processing, storage or degradation of medical devices shall be
especially considered. In addition, pollutants that are included in the packaging
materials and the interaction between the packaging materials and the pollutants shall
also be considered.
Since physical and chemical characteristics of materials are related with biological
safety, identification is also needed in this stage. This might involve any or several
aspects of content as follows.
-- Abrasion, loading and fatigue (especially load-bearing devices, for example, the
whole joint prosthesis) and relevant particles and material degradation products;
-- Abrasion and relevant stimulation, for example, the application of catheter;
-- Interaction (chemical action) among material compositions, such as different
flexibility, potential corrosion and abrasion;
-- Heat (for example, material variation caused by thermal degradation or other
heat);
-- The manufacturing process, for example, the generated internal stress can
stimulate environmental stress cracking (ESC), morphological change or
degradation;
-- The role of the environment, such as, endoscope (stomach aid), dressing
(external environment), ultraviolet light, detergent, and decontamination and
sterilization process;
-- Electricity, such as short circuit, degradation, heating and muscle stimulation;
-- The potential effect among different components;
-- The role of physical form, for example, particle.
Material information can be obtained through literature review, supplier’s information,
speaking, there are no rigorous material requirement in terms of materials indirectly
exposed to patients, medical devices that are merely exposed to intact skin, and
devices that are not directly exposed to human tissue, infusion, mucous membrane or
damaged skin tissue.
5.1.4 Risk evaluation
Risk evaluation is established on the basis of risk analysis. In risk analysis, it is defined
that the next step after defining risks is to evaluate the significance of risks and identify
relatively severe risks that need to be reduced (risk control). After risk estimation, risks
that exceed a certain stipulated level need to be reduced. It shall be recognized that
evaluation that includes th...
Need delivered in 3-second? USA-Site: YY/T 1512-2017
Get Quotation: Click YY/T 1512-2017 (Self-service in 1-minute)
Historical versions (Master-website): YY/T 1512-2017
Preview True-PDF (Reload/Scroll-down if blank)
YY/T 1512-2017: Biological evaluation of medical devices—Guidance on the conduct of biological evaluation within a risk management process
YY/T 1512-2017
YY
PHARMACEUTICAL INDUSTRY STANDARD
OF THE PEOPLE’S REPUBLIC OF CHINA
ICS 11.040.01
C 30
Biological Evaluation of Medical Devices -
Guidance on the Conduct of Biological
Evaluation within a Risk Management Process
(ISO/TR 15499.2016, MOD)
ISSUED ON. JULY 17, 2017
IMPLEMENTED ON. JULY 1, 2018
Issued by. China Food and Drug Administration
Table of Contents
Foreword ... 3
Introduction ... 5
1 Scope ... 7
2 Normative References ... 7
3 Terms and Definitions ... 8
4 Biological Evaluation is a Risk Management Activity ... 9
5 Risk Management Guidance ... 13
6 Guidance of Biological Evaluation in Specific Aspects ... 17
References ... 25
Foreword
This Standard is drafted in accordance with stipulations in GB/T 1.1-2009.
This Standard is modified in accordance with the Law of Redrafting on the basis of
ISO/TR 15499.2016 Biological Evaluation of Medical Devices - Guidance on the
Conduct of Biological Evaluation within a Risk Management Process.
In comparison with ISO/TR 15499.2016, there are several technical differences and
causes for these differences as follows.
-- In terms of normative references, there is an adjustment of technical differences
in this Standard to comply with national-level technical conditions. The condition
of such adjustment is intensively reflected in Chapter 2 “Normative References”.
Please see the specific adjustment below.
GB/T 16886.1-2011, which adopts equivalent international standards, is
adopted to replace ISO 10993-1.2009;
GB/T 16886.7, which adopts equivalent international standards, is adopted to
replace ISO 10993-7;
GB/T 16886.9, which adopts equivalent international standards, is adopted to
replace ISO 10993-9;
GB/T 16886.12, which adopts equivalent international standards, is adopted to
replace ISO 10993-12;
GB/T 16886.13, which adopts equivalent international standards, is adopted to
replace ISO 10993-13;
GB/T 16886.14, which adopts equivalent international standards, is adopted to
replace ISO 10993-14;
GB/T 16886.15, which adopts equivalent international standards, is adopted to
replace ISO 10993-15;
GB/T 16886.16, which adopts equivalent international standards, is adopted to
replace ISO 10993-16;
GB/T 16886.17, which adopts equivalent international standards, is adopted to
replace ISO 10993-17;
GB/T 16886.18, which adopts equivalent international standards, is adopted to
replace ISO 10993-18;
GB/T 16886.19, which adopts equivalent international standards, is adopted to
replace ISO 10993-19;
YY/T 0287-2017, which adopts equivalent international standards, is adopted
to replace ISO 13485.2016;
YY/T 0316-2016, which adopts equivalent international standards, is adopted
to replace ISO 14971.2007;
CNAS-CL01, which adopts equivalent international standards, is adopted to
replace ISO/IEC 17025.
Please be noted that certain content in this Standard might involve patents. The
institution that issues this Standard shall not undertake any responsibility of identifying
these patents.
This Standard is proposed by State Food and Drug Administration of the People’s
Republic of China.
This Standard is summarized by National Technical Committee 248 on Medical Device
Biological Evaluation Standardization (SAC/TC 248).
This Standard is drafted by. Shandong Quality Inspection Center for Medical Devices.
The main drafters of this Standard include. Liu Chenghu, Houli, Wuping.
Introduction
0.1 General Principles
This Standard provides guidance on the conduct of biological evaluation of medical
devices in accordance with the requirements in GB/T 16886.1-2011. Although GB/T
16886.1-2011 provides a general framework to the biological evaluation of medical
devices, more specific guidance is necessary during the practical application of this
Standard. Therefore, this Standard is formulated to provide guidance to users of GB/T
16886.1-2011. This Standard facilitates better understanding of the requirements in
GB/T 16886.1-2011 and elaborates various modes and methods that comply with the
requirements in GB/T 16886.1-2011.
Biological evaluation is a group of relatively broad design and verification activities
within the category of risk management process. Therefore, this Standard includes the
guidance of applying GB/T 16886.1-2011 during the risk management process in
accordance with the requirements in YY/T 0316-2016. As a part of the general
evaluation and development of medical devices, concepts and methods described in
this Standard can be taken into consideration during the establishment and
maintenance of a risk management process of biological evaluation.
With the scientific development, we have continuously intensified our grasp of the
fundamental mechanism of tissue reaction. Biological evaluation can be established
on the basis of the review of relevant scientific data, chemical analysis and necessary
in-vivo and in-vitro test. GB/T 16886.1-2011 stipulates a framework of planning
biological evaluation. Through the preferred adoption of chemical components, and in-
vitro models that can obtain equivalent relevant information with in-vivo models, the
quantity of experimental animals and the degree of exposure are controlled to the
minimum. The selection of an appropriate method for a specific medical device will
depend on the characteristics of the device, the availability of of relevant scientific data
and risk assessment.
During the assessment of the availability of the guidance in this Standard, the
requirements and guidance of applicable laws and regulations shall be taken into
consideration.
Organization groups can voluntarily include the whole or any part of the guidance in
this Standard in their risk management process.
The guidance included in this Standard can be assessed as background information
by assessors in the risk management process in institutions and regulatory authorities.
0.2 The Relations Among other Standards, Guidance Standards and
Regulatory Requirements
The relations among GB/T 16886.1-2011, this Standard, and medical device biological
Biological Evaluation of Medical Devices -
Guidance on the Conduct of Biological
Evaluation within a Risk Management Process
1 Scope
This Standard is applicable to the biological evaluation of medical devices in
accordance with the requirements in GB/T 16886.1-2011. This Standard does not add
or modify the requirements in GB/T 16886.1-2011. This Standard does not include
requirements of regulatory inspection or certification and assessment activities.
This Standard is applicable to all the biological evaluation of various types of medical
devices, including active, passive, implantable and non-implantable medical devices.
2 Normative References
The following documents are indispensable to the application of this Standard. In terms
of references with a specified date, only versions with a specified date are applicable
to this Standard. The latest version (including all the modifications) of references
without a specified date is also applicable to this Standard.
GB/T 16886.1-2011 Biological Evaluation of Medical Devices - Part 1. Evaluation
and Testing within a Risk Management Process (ISO 10993-1.2009, IDT)
GB/T 16886.7 Biological Evaluation of Medical Devices - Part 7. Ethylene Oxide
Sterilization Residuals (GB/T 16886.7-2015, ISO 10993-7.2008, IDT)
GB/T 16886.9 Biological Evaluation of Medical Devices - Part 9. Framework for
Identification and Quantification of Potential Degradation Products (GB/T 16886.9-
2001, ISO 10993-9.1999, IDT)
GB/T 16886.12 Biological Evaluation of Medical Devices - Part 12. Sample
Preparation and Reference Materials (GB/T 16886.12-2005, ISO 10993-12.2002,
IDT)
GB/T 16886.13 Biological Evaluation of Medical Devices - Part 13. Identification
and Quantification of Degradation Products from Polymeric Medical Devices
(GB/T 16886.13-2001, ISO 10993-13.1998, IDT)
GB/T 16886.14 Biological Evaluation of Medical Devices - Part 14. Identification
is a fundamental element of this biological evaluation plan. Patients obtain benefits
from the application of medical devices, and meanwhile, they also undertake potential
risks. These risks might differ in accordance with the characteristics and expected
purposes of specific medical devices. The acceptable level of risks of a specific
medical device is determined by the expected earnings of the medical device.
The consideration of biological (toxicological) risks of medical devices is merely an
aspect of various aspects that need to be taken into consideration during risk
assessment. Under some circumstances, the earnings of other characteristics, other
than the biological safety of materials, deserve special attention. For instance, the
optimal biologically safe material that can be obtained might not manifest acceptable
mechanical strength. Under this circumstance, it is necessary to consider materials
with a higher strength and acceptable biological safety. The premise of conducting
biological evaluation is to recognize that this is merely a part of the whole risk
management process that is needed for the design and development of medical
devices.
Material selection and risk analysis are organic constituent parts of medical device
design. The selection of materials plays a decisive role in biological safety evaluation.
Furthermore, relevant data can be collected by starting with a systematic mode. In
accordance with YY/T 0287-2017 and Y/T 0316-2016, criteria of acceptable biological
(toxicological) risks shall be determined at the beginning of design. Since the variation
of primitive materials, ingredients and process might influence the biocompatibility of
products, these considerations shall be included in risk assessment. Biological safety
evaluation shall be designed and conducted to verify the compliance with specific
safety criteria. As a constituent part of risk management plan, this evaluation is
centralized in the identification of hazards and the estimation of relevant risks. In
thorough risk assessment, toxicological hazards and the degree of exposure shall be
characterized.
A main content of hazard identification is material characterization, including.
-- Definition and characterization of each variety of material (including appropriate
alternative material);
-- Identification of hazards, additives and processing aids in materials;
-- Identification of the potential influence of downstream processing process (for
example, chemical reaction in material composition or sterilization of ultimate
products) on chemicals in the ultimate products;
-- Identification of chemicals that might be released during the usage of products
(for example, the intermediate or ultimate degradation product of a certain
degradable implant);
-- Estimation of intake (total intake or clinical intake);
of exposure of material composition. In risk analysis, each route of exposure and toxic
effect of risk of each variety of material/material composition shall be estimated in a
well-organized order.
Therefore, materials and material compositions on medical devices that are directly
and indirectly exposed to patients shall be identified and characterized first in risk
analysis. In consideration of the existence of any production additives, processing aids
or other potential pollutants, for example, disinfectant, risk analysis shall be conducted
on the ultimate product under the state of manufacture. Furthermore, the influence of
the processing process on material compositions and chemicals shall also be taken
into consideration (including the influence on the basal body and the surface). The
possibility of generating toxic residues in continuous application of medical devices, or
in the production, processing, storage or degradation of medical devices shall be
especially considered. In addition, pollutants that are included in the packaging
materials and the interaction between the packaging materials and the pollutants shall
also be considered.
Since physical and chemical characteristics of materials are related with biological
safety, identification is also needed in this stage. This might involve any or several
aspects of content as follows.
-- Abrasion, loading and fatigue (especially load-bearing devices, for example, the
whole joint prosthesis) and relevant particles and material degradation products;
-- Abrasion and relevant stimulation, for example, the application of catheter;
-- Interaction (chemical action) among material compositions, such as different
flexibility, potential corrosion and abrasion;
-- Heat (for example, material variation caused by thermal degradation or other
heat);
-- The manufacturing process, for example, the generated internal stress can
stimulate environmental stress cracking (ESC), morphological change or
degradation;
-- The role of the environment, such as, endoscope (stomach aid), dressing
(external environment), ultraviolet light, detergent, and decontamination and
sterilization process;
-- Electricity, such as short circuit, degradation, heating and muscle stimulation;
-- The potential effect among different components;
-- The role of physical form, for example, particle.
Material information can be obtained through literature review, supplier’s information,
speaking, there are no rigorous material requirement in terms of materials indirectly
exposed to patients, medical devices that are merely exposed to intact skin, and
devices that are not directly exposed to human tissue, infusion, mucous membrane or
damaged skin tissue.
5.1.4 Risk evaluation
Risk evaluation is established on the basis of risk analysis. In risk analysis, it is defined
that the next step after defining risks is to evaluate the significance of risks and identify
relatively severe risks that need to be reduced (risk control). After risk estimation, risks
that exceed a certain stipulated level need to be reduced. It shall be recognized that
evaluation that includes th...
Share











