GB 26386-2011: General safety technical specification for burnable incense
GB 26386-2011
GB
NATIONAL STANDARD OF THE
PEOPLE?€?S REPUBLIC OF CHINA
ICS 13.120
Y 40
General safety technical specification for burnable
incense
ISSUED ON: MAY 12, 2011
IMPLEMENTED ON: SEPTEMBER 15, 2011
Issued by: General Administration of Quality Supervision, Inspection and
Quarantine of PRC;
Standardization Administration of PRC.
Table of Contents
Foreword ... 3??
1 Scope ... 4??
2 Normative references ... 4??
3 Terms and definitions ... 4??
4 Categories... 5??
5 Requirements ... 5??
6 Test method ... 6??
7 Inspection rules ... 7??
8 Marking, packaging, transportation, storage ... 8??
Appendix A (Normative) Test method of soot amount of burnable incense
products ... 10??
General safety technical specification for burnable
incense
1 Scope
This standard specifies the terms and definitions, classification, requirements,
test methods, markings, packaging, transportation, storage of burnable incense
products.
This standard applies to solid incense, which is used in public places, such as
religion, etiquette, sacrifices, AND to improve indoor and outdoor environments.
2 Normative references
The following documents are essential to the application of this document. For
the dated documents, only the versions with the dates indicated are applicable
to this document; for the undated documents, only the latest version (including
all the amendments) is applicable to this standard.
GB/T 191 Packaging - Pictorial marking for handling of goods
GB/T 2828.1-2003 Sampling procedures for inspection by attributes - Part 1:
Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot
inspection
GB/T 2829-2002 Sampling procedures and tables for periodic inspection by
attributes (Apply to inspection of process stability)
GB/T 26393 Test methods for harmful matter of burnable incense
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Odor type
It is used to describe the overall aroma type in burnable incense products,
such as sandalwood, jasmine, rose, etc.
e) Specification and quantity;
f) Inspection conformity mark;
g) Precautions and warning words, such as: "Be careful after lighting."
8.1.2 The product packaging box shall have the following Chinese signs:
a) Product name;
b) The name and address of manufacturer;
c) Specification and quantity;
d) Pictorial signs for storage and transportation.
8.1.3 The pictorial signs for, packaging, transportation, storage shall meet the
requirements of GB/T 191.
8.2 Packaging
The packaging shall be firm, free from damage, squeezing and moisture proof.
8.3 Transportation
The product shall be protected from rain and snow, during transportation. When
handling, please load and unload with care; don't press it heavily.
8.4 Storage
The product is stored in a ventilated and dry place; kept away from fire sources
during storage; the distance between the stacking position and the ground and
the wall is not less than 20 cm.
A.3.1 Temperature: (23 ?? 5) ??C.
A.3.2 Relative humidity: (65 ?? 15)%.
A.4 Test procedure
A.4.1 Sample test
Place the sample to be tested and the filter paper in a drier, for 4 hours. Start
the test (it needs removing the exposed bamboo part from the bamboo incense).
Use an analytical balance to weigh the filter paper, as m1 (accurate to 0.1 mg).
Fix it on the sampling head. The sampling head is installed at the center of the
upper cover of the smoke collection tube. Cut 0.6 g from the sample to be tested,
accurate to 0.1 mg. Weigh its mass m, as the sample to be tested. It can be cut
into multiple segments as needed, BUT it must be ignited at the same time.
Adjust the sampling gas flowmeter to 5 L/min. Ignite the sample to be tested.
Immediately put it in the smoke collection tube. Place it at the center of the
bottom of the tube. Align it with the sampling head. The distance between the
sampling filter paper and the sample to be tested is 10 cm. After the test sample
is burned out, remove the filter paper. Put it in the drier. After 1 h, use an
analytical balance to weigh its mass, as m2 (accurate to 0.1 mg). Record the
time from ignition to burnout, as t.
A.4.2 Blank test
Take a piece of filter paper. Use an analytical balance, to weigh its mass, as m3
(accurate to 0.1 mg). Fix the filter paper on the sampling head. Install the
sampling head, at the center of the upper cover of the smoke collection tube.
Adjust the flowmeter to 5 L/min; the collection time is t (A.4.1). After collection,
remove the filter paper. Put it in a drier. After 1 hour, use an analytical balance
to weigh its mass, as m4 (accurate to 0.1 mg).
A.5 Calculation
The amount of soot of the tested sample is calculated, according to formula
(A.1):
Where:
X - The amount of soot, in milligrams per gram (mg/g);
m1 - The mass of the filter paper, before sampling, for the sample test, in
grams (g);
Need delivered in 3-second? USA-Site: GB 26386-2011
Get Quotation: Click GB 26386-2011 (Self-service in 1-minute)
Historical versions (Master-website): GB 26386-2011
Preview True-PDF (Reload/Scroll-down if blank)
GB 26386-2011: General safety technical specification for burnable incense
GB 26386-2011
GB
NATIONAL STANDARD OF THE
PEOPLE?€?S REPUBLIC OF CHINA
ICS 13.120
Y 40
General safety technical specification for burnable
incense
ISSUED ON: MAY 12, 2011
IMPLEMENTED ON: SEPTEMBER 15, 2011
Issued by: General Administration of Quality Supervision, Inspection and
Quarantine of PRC;
Standardization Administration of PRC.
Table of Contents
Foreword ... 3??
1 Scope ... 4??
2 Normative references ... 4??
3 Terms and definitions ... 4??
4 Categories... 5??
5 Requirements ... 5??
6 Test method ... 6??
7 Inspection rules ... 7??
8 Marking, packaging, transportation, storage ... 8??
Appendix A (Normative) Test method of soot amount of burnable incense
products ... 10??
General safety technical specification for burnable
incense
1 Scope
This standard specifies the terms and definitions, classification, requirements,
test methods, markings, packaging, transportation, storage of burnable incense
products.
This standard applies to solid incense, which is used in public places, such as
religion, etiquette, sacrifices, AND to improve indoor and outdoor environments.
2 Normative references
The following documents are essential to the application of this document. For
the dated documents, only the versions with the dates indicated are applicable
to this document; for the undated documents, only the latest version (including
all the amendments) is applicable to this standard.
GB/T 191 Packaging - Pictorial marking for handling of goods
GB/T 2828.1-2003 Sampling procedures for inspection by attributes - Part 1:
Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot
inspection
GB/T 2829-2002 Sampling procedures and tables for periodic inspection by
attributes (Apply to inspection of process stability)
GB/T 26393 Test methods for harmful matter of burnable incense
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Odor type
It is used to describe the overall aroma type in burnable incense products,
such as sandalwood, jasmine, rose, etc.
e) Specification and quantity;
f) Inspection conformity mark;
g) Precautions and warning words, such as: "Be careful after lighting."
8.1.2 The product packaging box shall have the following Chinese signs:
a) Product name;
b) The name and address of manufacturer;
c) Specification and quantity;
d) Pictorial signs for storage and transportation.
8.1.3 The pictorial signs for, packaging, transportation, storage shall meet the
requirements of GB/T 191.
8.2 Packaging
The packaging shall be firm, free from damage, squeezing and moisture proof.
8.3 Transportation
The product shall be protected from rain and snow, during transportation. When
handling, please load and unload with care; don't press it heavily.
8.4 Storage
The product is stored in a ventilated and dry place; kept away from fire sources
during storage; the distance between the stacking position and the ground and
the wall is not less than 20 cm.
A.3.1 Temperature: (23 ?? 5) ??C.
A.3.2 Relative humidity: (65 ?? 15)%.
A.4 Test procedure
A.4.1 Sample test
Place the sample to be tested and the filter paper in a drier, for 4 hours. Start
the test (it needs removing the exposed bamboo part from the bamboo incense).
Use an analytical balance to weigh the filter paper, as m1 (accurate to 0.1 mg).
Fix it on the sampling head. The sampling head is installed at the center of the
upper cover of the smoke collection tube. Cut 0.6 g from the sample to be tested,
accurate to 0.1 mg. Weigh its mass m, as the sample to be tested. It can be cut
into multiple segments as needed, BUT it must be ignited at the same time.
Adjust the sampling gas flowmeter to 5 L/min. Ignite the sample to be tested.
Immediately put it in the smoke collection tube. Place it at the center of the
bottom of the tube. Align it with the sampling head. The distance between the
sampling filter paper and the sample to be tested is 10 cm. After the test sample
is burned out, remove the filter paper. Put it in the drier. After 1 h, use an
analytical balance to weigh its mass, as m2 (accurate to 0.1 mg). Record the
time from ignition to burnout, as t.
A.4.2 Blank test
Take a piece of filter paper. Use an analytical balance, to weigh its mass, as m3
(accurate to 0.1 mg). Fix the filter paper on the sampling head. Install the
sampling head, at the center of the upper cover of the smoke collection tube.
Adjust the flowmeter to 5 L/min; the collection time is t (A.4.1). After collection,
remove the filter paper. Put it in a drier. After 1 hour, use an analytical balance
to weigh its mass, as m4 (accurate to 0.1 mg).
A.5 Calculation
The amount of soot of the tested sample is calculated, according to formula
(A.1):
Where:
X - The amount of soot, in milligrams per gram (mg/g);
m1 - The mass of the filter paper, before sampling, for the sample test, in
grams (g);